Engineers in Action

×
View More
GR130A Series Identifier Test Method GR130A-
00-30GY
GR130A-
00-50GY
GR130A-
00-100GY
Thickness mm Fujipoly   0.3mm ± 0.06mm 0.5mm ± 0.10mm 1.0mm ± 0.20mm
Thermal Resistance (°C•in2/W) FTM P-3050
(ASTM D5470
Equivalent)
14.5 psi 0.3 0.4 0.7
°C•cm2/W (100kPa) (0.04) (0.06) (0.11)
43.5 psi 0.2 0.3 0.6
(300kPa) (0.03) (0.05) (0.09)
72.5 psi 0.2 0.3 0.5
(500kPa) (0.03) (0.05) (0.08)
Color Visual Fujipoly   Light Gray    
Thermal Conductivity Watt/m•K ASTM D5470    13    
Volume Resistivity MΩ•m ASTM D257   1.0x1010    
Withstand Voltage kV/min ASTM D149   14    
Specific Gravity - ASTM D792   3.0    
Hardness Shore OO ASTM D2240   74    
Compression (N@10%) (area=25x25mm)        
50% sustain after 1 minute   835 845 350
    (189.2) (191.4) (79.3)
GR130A Series Identifier Test Method GR130A-00-150GY GR130A-00-200GY
Thickness mm Fujipoly   1.5mm ± 0.20mm 2.0mm ± 0.30mm
Thermal Resistance °C•in2/W FTM P-3050
(ASTM D5470
Equivalent)
14.5 psi 1.0 1.3
(°C•cm2/W) (100kPa) (0.16) (0.20)
43.5 psi 0.8 1.0
(300kPa) (0.13) (0.15)
72.5 psi 0.7 0.7
(500kPa) (0.11) (0.11)
Color Visual Fujipoly  Light Gray    
Thermal Conductivity Watt/m•K ASTM D5470  13    
Volume Resistivity MΩ•m ASTM D257  1.0x1010    
Withstand Voltage kV/min ASTM D149  14    
Specific Gravity - ASTM D792  3.0    
Hardness Shore OO ASTM D2240  74    
Compression (N@10%) (area=25x25mm)      
50% sustain after 1 minute   289 182
    (65.5) (41.2)

How can We Help You?